Cameras that have run viva-genicam
Each camera below has run the library, as an issue or pull request shows; the link is the evidence, and nothing here goes beyond it. Reported is what the person with the camera said they saw. Inferred is what we concluded from what they sent us: an XML file, a log, a capture. A fix that was never run again on the camera says so.
What does not work yet, on any camera, is issue #191. If your camera is missing here, or does something this page does not say, tell us: a report from your camera is how this list grows.
GigE Vision
Anonymous six-sensor GigE device
GigE Vision 1.2; the manufacturer, model and unique identifiers are private. Maintainer test on macOS/Apple silicon, 1 Gb/s Ethernet, MTU 1500. One stream contains six side-by-side Mono8 images. The initial run exposed reversed controller IP/port register contents; the transport accepts that layout only when both values match its socket. Short runs delivered six full 720 × 540 images at 30 FPS without reported loss. Each sensor’s test pattern was checked in its own image tile. C GenTL and Harvesters each received 1000 complete frames. Faster minimum-ROI runs and Python delivery showed host backpressure drops; this is not a loss-free maximum-FPS or endurance claim. Events, chunks and metric 3D are not advertised by this interface. The fixes and tests are recorded in #224. The 2026-10-27 follow-up also verified Studio quick controls, compact preview, near-cap display pacing and remote controls after a software reset. Preloading NumPy avoided the measured Python startup drops. A larger delivery queue then passed short production CLI checks at the minimum ROI and full six-sensor ROI; this is not endurance qualification. Detailed scope and restoration are in the bench record.
Allied Vision Manta G-125B
Firmware 00.01.44.28514, GigE Vision 1.2; macOS on Apple silicon, through a USB Ethernet adapter at MTU 1500. Run by the maintainer, so everything here is what was seen on the camera, with verbose logs. The 2026-10-25 run could not capture packets because access to the host’s BPF devices was denied.
- Discovery, including of the camera configured for another subnet, FORCEIP and persistent IP configuration (#215).
- Control and exclusive access, a second application refused while one holds control, a read-only monitor receiving another application’s multicast stream, commands, a saved configuration loaded back to the same 98 values, chunks in its GigE Vision 1.x layout, and events (#216).
- Streaming in every pixel format it offers, a 300 s stream at 30.9 fps with no frame lost, packet resend, packet pacing, multicast with a monitor, acquisition modes and software triggers, event timing, action commands (which it does not implement) and its clock (#217).
- A two-hour endurance run: 222,375 complete frames, one incomplete frame, no missed frames or delivery backpressure; resident memory stayed bounded and 15 files remained open. A separate ten-minute run delivered 18,531 complete frames without loss. These are measurements, not a loss-free eight-hour qualification.
- On 2026-10-25, all 24 hardware tests passed again. The C GenTL consumer and Harvesters each acquired ten complete 1292 × 964 Mono8 frames; Python discovery, feature reads, command execution and three NumPy-backed image captures passed.
- The service published 92 image messages in three seconds and resumed acquisition after an expired heartbeat and temporary IP change. A native Studio debug bundle discovered this camera but failed to claim control with
Broken pipe; its cause remains unconfirmed. The eight-hour follow-up started on 2026-10-25 and is still pending. - The recovery and surface checks above are recorded in #218; its eight-hour endurance result is pending.
- The hardware smoke suite,
crates/viva-genicam/tests/gige_hardware.rs, passes on it (#216, #217).
JAI FS-3200T-10GE-NNC
Windows 11 and Linux, link-local (APIPA) addressing; run by a user. Some threads call it a Vieworks FS3200T: the reporter wrote “JAI / Vieworks FS-3200T-10GE”, and discovery reports JAI Corporation.
- Reported: discovery on Windows after the fix in #64, and FORCEIP, with a capture we parsed and found to match (#57).
- Reported: on Linux, discovery, the XML download, 1 065 features loaded and streaming once the firewall let GVSP in (#57).
- Reported: 15 s of streaming on Windows through
viva-camctl, 46 frames and none dropped (#72); a later run onmain, 31 frames and none dropped, which we identified as this camera from its MAC address (#70). - Reported: live frames in Viva Studio’s embedded mode
(#87), and
viva-servicediscovering and connecting on Windows by address and by adapter GUID (#109). - Reported: the automatic packet size gave no frames in Studio, and the cause
was a switch on the path
(#112). The
fixes that followed have not been run on the camera; reads of its event
registers refused with
BAD_ALIGNMENTare still open there.
JAI GOX-2450SC-5GE
Windows 11, Viva Studio; run by a user. Reported: discovery, connection and its features in Studio. Acquisition failed on a host-side defect, since fixed, and has not been reported on this camera since (#70).
Micro-Epsilon scanCONTROL 8500-50
A GigE Vision laser profile scanner, firmware 3.0.0; run by a contributor.
- Reported: discovery with
viva-camctl(#95). - Reported: streaming its
Coord3D_ABC32fprofiles through the library, 755 568 frames with none dropped (#93). - Reported: how it answers control-channel reads while a command is pending
(
PENDING_ACK) and when its 5 s heartbeat expires, and, on the published 0.8.0 crates, a 5.1 MB file download (#163).
LUCID Triton2 EVS TRT009S-E
An event-vision camera (Sony IMX636); run by a contributor, on Linux as we read from its interface name.
- Reported: control through the library
(#138), and
streaming its EVT event data with
viva-camctl stream --raw-out(#154). - Reported: “Works”, with its GenApi XML, which is now in the vendor corpus (#138). The report does not say which version or command it ran.
- The EVT decoder’s tests use bytes captured from this camera (#139).
Basler a2A4096-44g5m
NixOS (Linux), the 0.9.0 crates; run by a user (#210).
- Reported: discovery, connection, writing
PixelFormatandAcquisitionMode, and one 4096 × 3000Mono8image, saved through the reporter’s own workaround for the stream port. - Reported:
TriggerSelectorfailed to resolve on 0.9.0 and worked onmain;TriggerModestill could not be read. The fix in 0.10.0 was checked against the camera’s XML only.
Hikrobot MV-CS050-10GC
Arch Linux; run by a user. Reported: discovery, and a connection — XML fetched and its node map built — after three fixes to how its XML is read (#35). Streaming was not reported.
FLIR Blackfly S BFS-PGE-31S4C-C
macOS, link-local addressing, the Python package; run by a user.
- Reported: the camera connects on 0.3.0 after it had failed to open (#45).
- Reported: discovery and opening with
viva-camctlon 0.4.1 (#120). WritingExposureTimewas refused as unavailable; the fix in 0.5.0 rests on its XML and has not been run on the camera.
FLIR Blackfly (model not stated)
Run by a user. Reported: one of its PTP registers sometimes failed to read on 0.5.0, and the fix worked on the camera (#140).
The Imaging Source DMK 33GP2000e
Ubuntu 24.04; run by a user. Reported: discovery and the XML download on
0.4.1, then a failure to parse the XML
(#122); the fix in
0.5.0 has not been reported run on the camera. On 0.6.0, a capture of a “dmk
camera” showed every packet-size write sent as WRITEREG
(#136).
Cameras whose model was not given
- Viva Studio’s embedded mode on Ubuntu, against an unnamed camera: no more refused reads on 0.6.0 (#135).
- Several identical cameras told apart by serial on 0.6.0 (#137).
USB3 Vision
MATRIX VISION mvBlueFOX3-2004G
macOS on Apple silicon over a USB 2 (High Speed) link behind a hub, and Windows; run by the maintainer.
- Bootstrap registers, streaming, chunks, events, the host clock, the cable
pulled mid-stream,
viva-service-u3vrescanning while it holds the camera, and the Python package (#205). - String and
<pLength>features, enumeration entries it does not offer, a saved configuration loaded back, and the USB3 Vision hardware suite (#206). - On Windows, after WinUSB was installed on the camera’s first interface, acquisition and Viva Studio (#208).